3. How to use

Temperature setting

You can set the required temperature gradually to a lower or higher value with the keys
(fig. A1).
EN
The temperature changes by 1 °C, in the convenience zone between 35 °C and 42 °C by 0.5 °C,
if key is pressed shortly one time. Pressing a key for a longer time changes the temperature
continuously.
Note: If temperature is set below 20 °C with key
switches off the heating function.
Note: If the water heater supplies a shower, the maximum temperature was reduced during initial
operation. This limitation cannot be exceeded.
Programme buttons
The two programme buttons allow to quickly select the preset temperature. When pressing a
programme key, the preset temperature is selected and displayed (fig. A2). The factory setting
for programme
is 35 °C and for programme
for the programme keys:
Prolonged pressing of the programme key stores the previously selected temperature. The
display changes from "P1" or "P2" to the newly stored temperature value. This newly set
temperature is now available to you each time you press the corresponding program key
(fig. A3).
For further informations please use the online operation and installation
instruction. Please follow the link below or use the QR code via smart-
phone or tablet.
https://www.clage.de/links/gma/DEX12-Next-L-GMA-9120-25724

4. Trouble-shooting and service

Repairs must only be carried out by authorised professionals.
If a fault in your appliance cannot be rectified with the aid of this table, please contact the service
organisation of your importer or the Central Customer Service Department. Please have the
details of the typeplate at hand.
CLAGE GmbH
After-Sales Service
Pirolweg 4
21337 Lüneburg
Germany
Phone:
+49 4131 8901-400
Email:
service@clage.de
and
the display shows "--" and the appliance
it is 48 °C. You can assign your own settings
DEX 12 Next L
Problem
Water stays cold, touch display
does not light up
Water stays cold, display
shows error symbol
Flow rate of hot
water too weak
Selected temperature is not
reached
Sensor keys does not respond
correctly or only sporadically
Each time you press a key, a sym-
bol appears
The display alternately shows P1
and 00
Venting after maintenance work
This instantaneous water heater features an automatic air bubble pro-
tection to prevent it from inadvertently running dry. Nevertheless, the
appliance must be vented before using it for the first time. Each time the
appliance is emptied (e.g. after work on the plumbing system, if there is
a risk of frost or following repair work), the appliance must be re-vented
before it is used again.
1.
Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to rinse out
the water pipe and avoid contaminating the appliance or the jet regulator.
3. Open and close the hot water tap until no more air emerges from the pipe and all air has
been eliminated from the water heater.
4. Only then should you re-connect the power supply again (e.g. via activating the fuses) to the
instantaneous water heater and screw the jet regulator back in.
5. The appliance activates the heater after approx. 10 seconds of continuous water flow.
Cleaning and maintenance
Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use abrasive or
chlorine-based cleaning agents or solvents.
For a good water supply, the outlet fittings (e.g. jet regulators and shower heads) should be
unscrewed and cleaned at regular intervals. Every three years, the electrical and plumbing
components should be inspected by an authorised professional in order to ensure proper
functioning and operational safety at all times.
This instantaneous water heater was manufactured conscientiously and checked several times
before delivery. Should malfunctions nevertheless occur, it is usually only due to a bagatelle. First
attempt to switch the house fuses off and on again in order to reset the electronics. Next, try to
remedy the problem with reference to the following table. In doing so, you will avoid unnecessary
expense of customer service assistance.
Cause
Master fuse tripped
Safety pressure cut-out tripped
The appliance has detected an error
Outlet fitting dirty or calcified
Fine filter dirty or calcified
Power limit reached
Cold water has been
added via the tap
Display is wet
Key lock active
Operation lock active
8
Solution
Renew or activate fuse
Contact customer service
Switch fuses off and on. If symbol "wrench" is
still indicated, contact customer service
Clean shower head, jet regulator or sieves
Let clean fine filter by customer service
Decrease the warm water flow at the tap
Tap hot water only; set temperature, check
outlet temperature
Dry display by wiping it with a soft cloth