11. Programming

If you need too long to complete programming, the programming process is interrupted.

a) Prematurely Ending Activation Delay

• After activation of the operating voltage (or after a power outage) LED (1) at the upper left of
the code lock will flash and the piezo buzzer will emit beeps for one minute (also see chapter
8).
• Enter the code
• The code lock emits two beeps and is then in regular operation. The LED (1) at the upper left
of the code lock is flashing orange slowly.

b) Activating/Leaving Programming Mode

• The LED (1) at the upper left at the code lock must flash slowly (orange); the code lock is in
regular operation.
• Enter the master code (default setting ex works "0000") and confirm your input by pushing the
star button twice.
The master code "0000" must be changed by you as described in chapter 11. d).
• The code lock emits two beeps and is then in programming mode. The LED (1) at the upper
left of the code lock is permanently lit (orange).
You can now perform the required programming; see description on the following pages.
Never disconnect the code lock from the operating voltage during programming. This
may damage the data or programming already present.
• Push the star button twice to leave programming mode.
The code lock emits two beeps and is then in regular operation. The LED (1) at the upper left
of the code lock is flashing slowly (orange).
and confirm your input with the
button.