Function 4: Locking/releasing output #1
Output #1 can be locked completely temporarily with the superuser code. Neither a user code
nor a transponder can operate output #1 then.
Example: The superuser code was programmed to be "6789":
While output #1 is locked, the left LED is lit red permanently (the LED also briefly flashes
orange).
Output #2 is not affected by the lock; the user codes and transponders will work there
as usual.

f) Shared Secondary Code for Outputs #1 and/or #2

Important!
If you switch on the "Auto-Entry" function (see chapter 11. m), all codes must have the
same length (e.g. master code + superuser code + secondary code 5 digits).
As already described in chapter 10, a code can be requested in addition to use of a transponder.
The secondary code set here applies to all transponders registered on the code lock each
(shared secondary code).
However, you can programme the secondary codes for output #1 and output #2 independently
of each other.
The secondary code alone cannot activate an output.
A valid transponder must be held to the sensor surface of the code lock first in any
case, and the secondary code must be entered then. Only then will the corresponding
output be activated (if the transponder and the secondary code are correct).
Programming secondary code for output #1
• The code lock must be in programming mode; see chapter 11. b).
• Enter the programming code
• Enter the secondary code for output #1, e.g.
• Confirm your input with the
• The code lock emits two beeps; the secondary code is saved.
When a new secondary code is programmed, it will overwrite the previous code.
Locking/releasing output #1
.
button.
.
83