16 Commissioning, setting parameters
Saving parameter value
To save, press the buttons
erfor 2 seconds. The ventilation level LEDs are
constantly lit up.
Exiting service mode
Press the
and
seconds.
The ventilation unit switches to the specified vent-
ilation level.
16.2 Parameter list, LEDs
LEDs – Meaning
LED flashes quickly, flashes slowly
(dimmed), lights up
Vertical LEDs flash quickly = change air filter
The following list shows the parameters
that can be set on the RLS 45 K control with
the associated LED displays. Parameters shown
in grey are without function on RV 2 units.
The following list shows the parameters that can
be set on the RLS 45 K control with the associ-
ated LED displays.
Parameters shown with bold font = RV 2
parameters.
Par. Function
1
Unit type on RLS
(Fan1, Fan2). With
RV 2 without function.
2
Number of unit pairs,
unit types. With RV 2
without function.
3
Deactivating ventila-
tion level 0
4
Power units, RLS
(on the RS 485 bus)
5
230 VAC input
6
Sensors
32
and
togeth-
buttons together for 5
LED
LED
LED
Par. Function
7
EnOcean
8
EnOcean Teach
mode. With RV 2
without function.
9
Number of PPB 30 K.
With RV 2 without
function.
10 ModBus settings. AT-
TENTION: The Mod-
Bus interface must
be deactivated for RV
2 units, otherwise the
RV 2 cannot be con-
trolled.
11 ModBus address.
With RV 2 without
function.
12 Plug & Play
16.3 Service mode setting
parameters
For further information on functions and settings
in the CDV commissioning software, see the RV 2
installation and commissioning instructions.
Factory settings for the following para-
meter setting values in bold.
Parameter 1: Unit type on RLS (Fan1, Fan2)
No function for RV 2.
Parameter 2: Number of unit pairs, unit types
PP 45 and PPB 30 O
No function for RV 2.
Parameter 3: Deactivating ventilation level 0
LED
LED
1 = Ventilation level 0 ac-
tivated.
2 = Ventilation level 0 deac-
tivated. The ventilation units
cannot be switched off on
this control. The units run at
least at level 1.
LED