17 Operation

Parameter 12: Plug & Play
Exit setting mode
Press the
and
seconds. The ventilation unit switches to the spe-
cified ventilation level.
16.4 Automatic search (Plug & Play)
For RV 2 and CPP 60 units when assigned in
pairs (even number of units).
In the automatic search, the factory-set unit ad-
dresses (100 to 250) of the individual ventilation
units are read out. The supply air and exhaust
air units of the same unit family (RV 2 or CPP
60) are then paired.
Alternatively, you can also carry out the process
manually using the CDV commissioning soft-
ware. This is required for an uneven number
of units. For manual configuration → RV 2 in-
stallation and commissioning instructions.
For RV 2 unit address, see sticker on the ter-
minal box cover.
Make sure that an even number of units from
the same unit family are installed and that no unit
address is used more than once (otherwise a
communication error will occur and the search will
not be saved). In this case, reconfigure the fact-
ory address of the individual units with the CDV
commissioning software.
Start automatic search
1. Call up the service menu.
2. Select the last parameter Plug & Play. The 3
LEDs on the left flash slowly.
34
Automatic search run for
pairwise assignment of the
supply air and exhaust air
units.
0 = Manual settings with
commissioning software
1 = Plug & Play: Start auto-
matic search
For further information →
following chapter.
buttons together for 5
3. Use
to select 1 = Start Plug & Play
search. During the search run, the ventilation
level LEDs light up (running light, approx. 1
minute). Cancel with
exhaust air units are automatically paired with
the determined unit addresses.
The values are saved after a successful search.
The number of units found is displayed with the
ventilation level LEDs.
The units are categorised in chronological order,
alternating between supply air and exhaust air
units.
Example with 4 ventilation units and addresses
110 / 180 / 185 / 220. Automatic categorisation as
follows: 110 = supply air / 180 = exhaust air / 185
= supply air / 220 = exhaust air.
0
1
2
Connected RV 2 ventilation units
0
No ventilation unit
1
1 ventilation unit
2
1 pair of units
3
2 pairs of units
4
3 pairs of units
5
4 pairs of units
Error when connecting an odd number
of units
If the search fails, the ventilation level LEDs in-
dicate a fault
and flash quickly.
The service menu is exited automatically
after 120 seconds and does not need to be
cancelled.
To delete the settings, select 1 = Start plug &
play search with
17 Operation
The ventilation system runs in continuous oper-
ation. Once the mains fuse has been switched
on, the LEDs of the selected operating mode and
ventilation level light up on the room air controls.
. The supply air and
3
4
.
5
Inhaltsverzeichnis