Wiring diagram of RV 2 with RLS 45 K
RLS 45 K Comfort room air control
RV 2 #1 PushPull ventilation unit 1
RV 2 #2 PushPull ventilation unit 2
RV 2 #3 PushPull ventilation unit 3
S1 Button/switch for additional functi-
on (sleep, intensive, disbalance
and safety function).
UP-L Flush-mounted distributor for fan
units: Connection of all fan units in
a star configuration to the distribu-
tor.
W-B1 Recommended control cable from
RLS 45 K control to star point/
distributor (max. 4 m):
Type J-Y(ST)Y 2x2x0.8 mm².
W-RV 2 (X) Recommended control cable from
RV 2 ventilation unit to star
point/distributor (max. 25 m):
Type LiYY 4x0.5 mm².
FR
Schéma de câblage RV 2 avec RLS 45 K
RLS 45 K Commande d'air ambiant Confort
RV 2 #1 Appareil de ventilation PushPull 1
RV 2 #2 Appareil de ventilation PushPull 2
RV 2 #3 Appareil de ventilation PushPull 3
S1 Touche/interrupteur fonction sup-
plémentaire (mode de mise en
veille, intensif, fonction de désé-
quilibre et de sécurité).
UP-L Diffuseur encastré unités de venti-
lation : Raccordement de toutes
les unités de ventilation au diffu-
seur.
W-B1 Câble de commande conseillé
Commande RLS 45 K jusqu'à
point neutre / diffuseur (max.
4 m) :
type J-Y(ST)Y 2x2x0,8 mm².
W-RV 2 (X) Câble de commande conseillé Ap-
pareil de ventilation RV 2 jusqu'à
point neutre/diffuseur (max.
25 m) :
type LiYY 4x0,5 mm².