SYMBOL GUIDE
The following symbols and safety labels are found on the MaxO2+:
Follow instructions for use
Warning
Meets ETL standards
DO NOT
Low Battery
Calibration Required
Caution
Federal law (USA) restricts
this device to sale by or on
order of physician
Manufacturer
Date of Manufacture
Atmospheric Pressure
Range
Unique Device Identifier
MR Unsafe
Single Use
ENGLISH
On/Off Button
Calibration Button
Do not throw away. Follow
local guidelines for disposal
%
Percent
Serial Number
Lot code/Batch code
Ingress Protection Rating
Authorized Representative
in the European
Community
Catalog Number
Medical Device
Responsible Person in the
UK
Applied Parts - Type BF
Temperature Range
Humidity Range
1 OVERVIEW
1.1 Indications for Use
MaxO2+ Oxygen analyzers are intended as tools for the use by trained personnel, under the
direction of a physician, to spot-check or measure oxygen concentration in air/oxygen mixtures
being delivered to patients ranging from newborns to adults. It can be used in pre-hospital,
hospital, and sub-acute settings. The MaxO2+ oxygen analyzers are not a life supporting device.
1.2 Essential Device Performance
Essential performance are the operating characteristics of the device without which would result
in an unacceptable risk. The following items are considered essential performance:
Oxygen measurement accuracy
1.3 Base Unit Description
The MaxO2+ analyzer provides unparalleled performance and reliability due to an advanced
design that includes the following features and operational benefits.
Extra-life oxygen sensor of approximately 1,500,000 O2 percent hours (2-year warranty)
Durable, compact design that permits comfortable, hand-held operation and easy to clean
Operation using only two AA Alkaline batteries (2 x 1.5 Volts) for approximately 5000 hours
of performance with continuous use. For extra extended long life, two AA Lithium batteries
may be used.
Oxygen-specific, galvanic sensor that achieves 90% of final value in approximately 15
seconds at room temperature.
Large, easy-to-read, 3 1/2-digit LCD display for readings in the 0-100% range.
Simple operation and easy one-key calibration.
Self-diagnostic check of analog and microprocessor circuitry.
Low battery indication.
Calibration reminder timer that alerts the operator, using a calibration icon on the LCD
display, to perform a unit calibration.