6
Default settings
Factory-set default settings have already been pro-
grammed in the control you received.
Please refer to the following table for the default set-
tings of specific functions:
Sauna operation:
Start of heating
Heating duration
Temperature
Fan
38
Operating instructions for the user 8
OFF no setting
6 hours
90° C
60 P
7
Faults and troubleshooting
7.1
Displayed error messages 5:
An error message signals an electrical defect of the sys-
tem.
The control is no longer ready-to-operate:
1. Write down the error message.
2. Shut off the main fuses of the control in
the fuse box.
3. Contact customer service.
4. Mark the control as being defective.
Using the following display error messages 5 you can
inform customer service of possible errors/defects.
The error messages mean:
Err 1:
Overtemperature sensor FI is
defective
Err 2:
Internal error
Err 3:
Break in sensor line FI
Err 4:
Short circuit in line
Err 5:
Short circuit in line FII
(temperature sensor)
Err 6:
Line interruption FII
(temperature sensor)
7.2
Cabin lighting does not work
Turn off switch 2.
•
•
Shut off the main fuses of the control in the fuse box.
•
Replace the light bulb.
Switch on the main fuses and activate switch 2.
•
•
Contact customer service, if the cabin lighting still does
not work.