Installation instructions for trained electricians only
3
Installing the control
Figures 2 6 7
Connecting the optional fan
6. Run the fan lines through opening H (connection
range for 230 V / 400 V I) into the base of the
housing 1 and connect according to circuit dia-
gram 6 to terminal K.
Connecting the optional power boost
7. Run the lines to be connected to terminals St1,
St2, St3 of the power boost unit through the ope-
ning G (connection range for 230 V / 400 V I)
into the base of the housing 1 and connect ac-
cording to circuit diagram 7 to terminal K (as
described under subitems of item 3.).
8. Connect all PE conductors to the ground terminals
D.
Fix tight bottom of housing
9. Fasten two, 20 mm long, Philips head screws in
the lower mounting holes 5.
Check secure fit of bottom of housing 1.
10. Fit the housing cover on the base of the housing
1 rotate it downwards and push down until you
hear it lock in position.
Check for secure fit of the control .
26
4
Installing the stove sensor FI
with overtemperature fuse
Figure 4
Install the stove sensor with overtemperature fuse in
the sauna cabin about 15 cm below the ceiling and
above the heating system, or in accordance with the
cabin manufacturer's specifications.
Use only the supplied 150° C temperature-resistant
connecting line or an equivalent temperature-resistant
line to connect the stove sensor with overtemperature
fuse.
On the outside of the sauna cabin, the temperature-
resistant connecting line can be extended with conven-
tional lines.
WARNING - Electric shock:
Run the power cables separate to other sen-
sor and control lines.
Protect single insulated lines with a pipe
(double insulation).
1. Run four-pin line 5 to mounting location of sto-
ve sensor 4 in the cabin wall and fix in position
with wiring clips.
2. Separate two half shells 1 of stove sensor 4
and connect four terminals of the temperature-re-
sistant line according to the circuit diagram (ob-
serve the color coding on the sensors which cor-
respond to the figures).
3. Insert round adapter plate 2 with the connections
crosswise in half shells 1, close half shells 1
and fix with the two 9 mm long Philips head screws
3.
Check for secure fit of stove sensor 4.
4. Conduct tests according to the chapter "Tests".
5. Bolt stove sensor 4 to the cabin wall in alignment
with the heater, keep a distance of 15 cm to the
ceiling, or install in accordance with the cabin
manufacturer's specifications, using two wood
screws 6.