SC1 - Start-up Conditions for Out 1
When the monitor has been switched on, output 1 switches in accordance with the
set switching function and the order of the input pulses:
• output 1 ON (status signal) for FO1 = 1 and pulse sequence In1 before In2 as well
as FO1 = 2 and pulse sequence In2 before In1.
• output 1 OFF (fault signal) for FO1 = 1 and pulse sequence In2 before In1 as well
as FO1 = 2 and pulse sequence In1 before In2.
In connection with ST1 (start-up delay time) the following start-up conditions can be
fixed by setting the parameter SC1:
SC1 = 1
OUT1 for FO1 = 1
OUT1 for FO1 = 2
SC1 = 2
OUT1 for FO1 = 1
OUT1 for FO1 = 2
• Range of values: 1 und 2.
• Presetting in the factory: 1.
Switching functions and switch points
FO1 - Function Output for Out 1
(switching function for output 1; direction monitoring):
F01 = 1
Relay energises / output transistor conductive (status signal) when pulse sequence
In1 is before In2. Once an order of pulses has been detected correctly the output
remains in this state until the direction is changed.
When pulse sequence In2 is before In1, the relay de-energises / the output transistor
is blocked (fault signal).
F01 = 2
Relay energises / output transistor conductive (status signal) when pulse sequence
In2 is before In1. Once an order of pulses has been detected correctly the output
remains in this state until the direction is changed.
When the pulse sequence In1 is before In2, the relay de-energises / the output tran-
sistor is blocked (fault signal).
The relay can either be reset by the active reset time or by front reset.
during ST
In1 before In2
OFF
OFF
remains OFF
during ST
In1 before In2
ON
remains ON
ON
switches OFF
when ST has elapsed
In2 before In1
ON
remains OFF
ON
when ST has elapsed
In2 before In1
switches OFF
remains ON
FD-1/FD-1N
MONITOR
no pulses
OFF
OFF
no pulses
switches OFF
switches OFF
page 41