FD-1/FD-1N
MONITOR
In case of malfunction of the unit or uncertainties please contact the manufacturer.
Tampering with the unit can seriously affect the safety of people and the plant.
This is not permitted and leads to an exclusion of liability and warranty.
2. Functions and features
The FD-1/FD-1 N monitor is a pulse evaluation system for direction and speed
monitoring.
For direction monitoring the monitor receives pulses from external pulse pick-ups
via 2 separate input channels, evaluates the pulse shifts (pulse sequence In1 before
In2 or the other way round) and switches output 1 according to the set parameters.
The input pulses must be phase-shifted and must overlap for a time of approx.
0.25 ms.
direction monitoring
The parameters of the monitor can be set in a way that the preset direction is either
left-hand movement or right-hand movement. When the preset direction is detect-
ed, the output relay energises / the transistor output switches (status signal), when
the opposite direction is detected, the relay de-energises / the transistor output is
blocked (fault signal).
page 34
IN1
IN2
MONITOR FD-1
Frequency/Direction
OUT1 OUT2
speed monitoring
switching cams
pulse pick-up
approx. 0.25ms
pulses In1 / In2