Error code
Error argument
steady, conti-
0 pulses
nuous flashing
1 pulse
0 pulses
1 pulses
2 pulses
2 pulses
0 pulses
n pulses (n>0)
3 pulses
0 pulses
4 pulses
0 pulses
Cause
Remedy
Problems with
Check power sup-
electromagnetic
ply for extremes
compatibility
in undervoltage
(EMC)
or overvoltage
Implement EMC
measures
If there is a K bus
error, the error
can be localised
by restarting the
field bus coupler
(switching it off
and on again)
EEPROM check
Set manufactu-
sum error
rer's setting with
the KS2000
Inline code buffer
Attach fewer ter-
overflow.
minals
Too many entries
in the table
Unknown data ty-
Update field bus
pe
coupler software
programmed con-
Check that pro-
figuration incor-
grammed confi-
rect table
guration is cor-
entry/bus coupler
rect
(Terminal n) table
Incorrect table
comparison incor-
entry/bus coupler
rect
Terminal bus
No terminal inser-
command error
ted, attach termi-
nal
A terminal is faul-
ty
Disconnect half
the terminals and
check whether
the error occurs
with the remai-
ning terminals.
Continue this
process until the
faulty terminal is
found
Terminal bus data
Check whether
error
the n+1 terminal
is correctly con-
nected and chan-
ge if necessary
43