App screen
BWT 14ROC CLINIC TP
TP
pump
cooling
0.1 l
20
[mmH2O]
160
TRANSPORT PUMP
II
BWT 14ROC CLINIC TP
fault
inlet
h2o meter
0.1 l
20
[mmH2O]
160
TRANSPORT PUMP
II
BWT 14ROC CLINIC TP
level
sensor
fault
0.1 l
20
[mmH2O]
160
TRANSPORT PUMP
II
BWT 14ROC CLINIC TP
tank
over
filled
0.1 l
20
[mmH2O]
160
TRANSPORT PUMP
II
LED flashing mode
ON
OFF
x7
ON
OFF
The status LED flashes
7 times in a row.
ON
OFF
x3
ON
OFF
The status LED re-
peatedly flashes three
times in succession.
ON
OFF
ON
OFF
Status LED lights up in
red and a warning sig-
nal sounds.
ON
OFF
x9
ON
OFF
The status LED flashes 9
times in a row.
Cause
The transfer pump
does not work or is not
connected.
The input water meter
is blocked or has no
power supply.
Problems with the tank
fill level sensor.
The tank is overfilled.
The fill level sensor in-
dicates a value that is
too high.
Measure
The device will start by
itself when the transfer
pump motor has
cooled down.
Permeate is still pro-
duced, but the volume
of the input water is
not recorded.
Check the power sup-
ply.
Contact your service
technician.
Contact your service
technician.
When the tap is
opened, the vessel is
emptied.
29