Herunterladen Diese Seite drucken

Carl Valentin Dynacode IP53 Kurzanleitung Seite 138

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 78
Dynacode IP
Key:
Transfer ribbon
advance warning
Key:
Write log files on MC
Main Menu
Switch on the direct print module and the display shows the main menu. The main menu shows information such as device
type, current date and time, version number of firmware and the used FPGA.
The selected display is shown for a short time, then the indication returns to the first information.
Press key
to arrive the next information display.
138
TRB = Transfer ribbon advance warning:
Before the end of transfer ribbon, a signal is send by the control output.
Warning diameter:
Setting of transfer ribbon advance warning diameter.
In case you enter a value in mm then a signal appears via control output when reaching this
diameter (measured at transfer ribbon roll).
Ribbon advance warning mode:
Warning: When reaching the transfer ribbon advance warning diamter, the corresponding I/O
output is set.
Error: The printing system stops when reaching the transfer ribbon advance warning diameter
with the message 'too less ribbon'.
With this command, different log files are saved on an existing storage medium (memory card or
USB stick). After the 'Finish' message the storage medium can be removed.
The files are in directory 'log':
LogMemErr.txt: Logged errors with additional information such as date/time and file name/line
number (for developers).
LogMemStd.txt: Logging of selected events.
LogMemNet.txt: Data latest send via port 9100.
Parameters.log: All printer parameters in human readable form.
TaskStatus.txt: Status of all printer tasks.
English

Werbung

loading

Diese Anleitung auch für:

Dynacode ip107Dynacode ip128