Installation instructions, only for experts
8.7. Displaying the heater temperature in single-sensor mode
In single-sensor mode, the sauna control unit only displays the set temperature as
standard. The actual temperature is not displayed. If the sauna control unit is to
display the temperature above the heater (F1 sensor) as the actual temperature in
single-sensor mode, this must be activated using the function selection switch 8.
● The function selection switch 8 is set to the ON position as standard. Therefore
only the set temperature is displayed.
● If the temperature above the heater is to be displayed as an actual tempera-
ture, place the function selection switch 8 in the OFF position.
Ensure that the temperature above the heater is always higher than the
temperature in the area of the bench seat. With the heater temperature
as the actual temperature, the temperature displayed by the sauna con-
trol unit is higher than the temperature measured by your sauna cabin
thermometer.
8.8. Settings in the technician menu
Opening the technician menu
Additional settings can be made in the technician menu. To access the technician
menu, perform the following steps:
1. The sauna control unit must be switched off
2. Simultaneously press the On/Off switch
the temperature selector
► "SEtt" will appear in the top display
3. Press the temperature selector
Setting the duration of the post-drying program (PRO B3 only)
The maximum duration of the post-drying program is set to 60 min as standard.
If you wish to change this setting, perform the following steps:
1. Open the technician menu
► "dry" will appear in the top display
► "t30" will appear in the bottom display
2. Use the temperature selector
0 = post-drying program switched off; 60 = maximum duration in minutes)
6
.
3
1
to access the setting you wish to change
3
1
to set the preferred value: (Selection 0–60;
3
, the preset time button
4
p. 26/38
and
7