Installation instructions, only for experts

4.2. Installing the heater sensor F1 with overheat cut-out

Note the following points when installing the heater sensor:
● The heater sensor must be installed on the rear of the heater, above the
middle of the sauna heater. A distance of about 15 cm from the ceiling of the
cabin must be maintained.
● The heater sensor must be installed in such a way that it is not affected by
inflowing air.
To install the heater sensor, carry out the following steps (see Fig.3):
1. Route the two 2-pole heater sensor cables in the wall of the sauna cabin
to the installation location of the heater sensor and affix the heater sensor
cables using cable clips.
2. Pull the two half-shells
3. Connect the four connections for the heater sensor lead
with Fig.3.
4. Place the connection panel
sensor half-shells.
5. Place the two half-shells together, screw them together using two cross-
head screws
securely closed.
6. Install the heater sensor on the rear of the heater using the two supplied
wood screws
of the heater sensor apart.
1
crossways (as shown in Fig.3) in the heater
2
(9 mm) and check whether the heater sensor has been
3
(16 mm).
6
in accordance
5
1
Heater sensor half-shells
2
Connection panel
3
Cross-head screws (9 mm)
4
Heater sensor
5
Heater sensor leads
6
Wood screws (16 mm)
Fig.3
Installing the
heater sensor
p. 15/38