Installation instructions, only for experts
8.3. Activating/deactivating phase alignment
Phase alignment is activated or deactivated using the function selection switch 3.
● The function selection switch 3 is set to the ON position as standard. Phase
alignment is therefore activated.
● If you wish to deactivate phase alignment, place the function selection switch 3
in the OFF position.
8.4. Remote start release
Function selection switch 4 can be used to select the function of the remote
start output
(please see EN 60335-2-53).
● Function selection switch 4 is set to the OFF position as standard. The remote
start is activated using "Standby for remote control".
● If you want to enable the remote start output for various devices (e.g. coin-op-
erated unit, remote start system, door monitoring), set function selection
switch 4 to the ON position.
8.5. Activating/deactivating the single-sensor mode
In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. The single-sensor mode must be
activated using the function selection switch 5.
● The function selection switch 5 is set to the ON position as standard. Two-sen-
sor mode is therefore activated.
● If you wish to deactivate single-sensor mode, place the function selection
switch 5 in the OFF position.
8.6. Activating vaporizer single mode (PRO B3 only)
The vaporizer is factory set so that it can only be operated together with the
heating system. To operate the vaporizer on its own without the heating system,
vaporizer single mode must be activated using the function selection switch 7.
● Function selection switch 7 is set to the OFF position as standard. This means
vaporizer single mode is deactivated.
● If you wish to activate vaporizer single mode, place the function selection
switch 7 in the ON position.
p. 25/38
EN