ANTI-FREEZE function
When the device is off but still has a live feed, and the temperature
inside the room falls down below 6°C the device will automatical-
ly turn on and start heating. This function will prevent the heating
medium inside the radiator from freezing. Yellow diode is flashing
until the temperature reaches 6°C.
TROUBLESHOOTING
Problem
Possible cause
Device is connected
Device is not turned on
to electricty, no diodes
are on, heating element
Problem with
does not heat
connection or power
supply
Heating element heats
Possible controller
allthough the device
damage
is off
Heating element does
Possible heating element
not heat, but the diodes
damage
are working properly
If the problem persists, please contact your local Distributor.
EN
FIL-PILOTE INTERFACE
Selected versions of the SKT-1 device are equipped with a FIL
PILOTE interface which enables remote heating control through
an external controller which conforms with FIL PILOTE standards.
SKT-1 reacts to 4 basic commands:
Signal
Problem solution
Turn the device on with
the
button
Check the connection of
the power supply wire.
Check that the voltage
is correct
Disconnect the device
completely from the
electricity source and
wait until it cools down
before switching it
back on
User Manual — Electric heating elements of the SKT series
FP Command
Reaction of the Controller
FP-COMFORT
Heating in accordance with
current setting
FP-ECO
Heating with heat output
reduced by 30% in relation to
the current setting
FP-AF
No heating, anti-freeze
function active
FP-STOP
Heating mode and anti-freeze
functions are both off