5.2.2 Electrical connection

Danger
Electric shock from live components
A fatal electric shock can occur when the warewasher and its additional devices are connected to the electrical mains
supply.
Ø
The warewasher and its additional devices may be connected to the electrical mains supply only by a specialist
company registered within the electrical trade and approved by the energy supplier.
Ø
All locally applicable standards and regulations must be observed during the connection to the electrical mains sup-
ply.
Ø
A protective circuit must be connected properly.
Ø
The electrical safety of this warewasher is guaranteed only if it is connected to a correctly installed protective circuit.
Ø
The wiring diagram must be observed.
Ø
The warewasher may be operated only at the voltages and frequencies specified on the rating plate.
Ø
For machines delivered without a plug, a fixed connection must be installed as an overriding priority.
Ø
We recommend installing a mains isolation switch with all-pole disconnection from the mains supply in the case of a fixed connec-
tion (without plug) so as to be able to ensure the absence of voltage during installation and maintenance.
Ø
The electrical connection must be secured as a separately fused circuit with slow fuses or circuit breakers. The fuse protection de-
pends on the total connected load of the warewasher. The total connected load is specified on the rating plate of the warewasher.
Ø
If a residual current circuit breaker is provided on-site, we recommend installing a Class B all-current sensitive residual current cir-
cuit breaker.
Ø
Machines delivered from the factory that are fitted with mains cable and safety plug (single-phase), or a CEE plug (triple-phase),
may only be connected to the mains network indicated on the nameplate. Machines may only be connected to an individually pro-
tected safety socket. Do not use extension cables or multi-socket adapters.
Ø
Determine the cable cross-section of the mains cable using the following table:
Mains voltage
380 V - 415 V / 3N~
220 V - 240 V, 1N~
200 V, 2~
200 V, 3~
230 V, 2~
230 V, 3~
The mains cable must be a H07RN-F type or equivalent.
Operating instructions
Frequency [Hz]
50 / 60
50 / 60
50 / 60
50 / 60
50
50
On-site fuse protection [A]
10 / 15 / 16 / 20
10 / 13 / 15 / 16 / 20
20
25
16
20 / 25
|
|
11208020/04; 2023-07
|
|
Commissioning
5
English
Cable cross-section [mm²]
2,5
2,5
2,5
4
2,5
4
57