5.2.2 Electrical connection

Danger
Electric shock from live components
A fatal electric shock can occur when the warewasher and its additional devices are connected to the electrical mains
supply.
Ø
The warewasher and its additional devices may be connected to the electrical mains supply only by a specialist
company registered within the electrical trade and approved by the energy supplier.
Ø
All locally applicable standards and regulations must be observed during the connection to the electrical mains sup-
ply.
Ø
When performing installation and maintenance work as well as repairs, unplug the warewasher from the mains sup-
ply. Check that there is no voltage present.
Ø
The electrical safety of this warewasher is guaranteed only if it is connected to a correctly installed protective circuit and a residual
current circuit breaker. It is crucial that this basic safety requirement is tested and, in case of doubt, that the on-site installation is
checked by a qualified electrician.
Ø
The circuit diagram must be observed.
Ø
The warewasher may be operated only at the voltages and frequencies specified on the rating plate.
Ø
For machines delivered without a plug, a fixed connection must be installed as an overriding priority.
Ø
The electrical connection must be secured as a separately fused circuit with slow fuses or circuit breakers. The fuse protection de-
pends on the total connected load of the warewasher. The total connected load is specified on the rating plate of the warewasher.
Ø
If a residual current circuit breaker is to be provided on-site, we recommend installing a Class B all-current-sensitive residual cur-
rent circuit breaker.
Ø
Determine the cable cross-section of the mains cable using the following table:
Voltage
Frequency [Hz]
380V, 3N~
400 V / 3N~
415 V / 3N~
200 V / 3~
230 V / 3~
230 V / 1N~
240 V / 1N~
The mains cable must be a H07RN-F type or equivalent.
Operating instructions PTD 901
On-site fuse protection [A]
50
60
50
60
50
60
50
60
50
60
50
60
50
60
16
16
25
32
15
16 / 20
25
32
25
32
25
32
32
25
32
40
50
|
|
12020302; 2021-09
|
|
Commissioning
5
English
Cable cross-section [mm²]
2,5
2,5
4
6
2,5
2,5
4
6
4
6
4
6
6
4
6
10
10
75