| Installation
F
G
Important!
• The unit requires regular maintenance and therefore kitchen furniture panel between cabinets where the unit is lo-
cated must be removable.
• Depending on the cupboard depth and selected kitchen furniture panel installation method, the SAVE VTR 100/B unit
may have to me shifted forward using wood blocks at the back.
• Solutions how to hang this panel are described further in this document, see 6.5 Installation of a kitchen furniture
panel, page 24.
Make sure to find a correct depth for installation of the SAVE VTR 100/B unit before proceeding with the mounting
bracket installation on the wall.
The SAVE VTR 100/B is supplied with approximately 1,9 m of power cable and fitted with a plug for 230 V~, single
phase earthed connection located at the top of the unit.
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic etc. Stale discharge air should ideally be led via a roof unit to
the outside and with a good distance to any outdoor air intake, windows etc.
6.3.1

Wall preparation for mounting bracket

The unit should be installed in such a way that there is no
vibration noise coming from the wall on which the unit is
installed.
Important
Make sure to read all instructions before
proceeding with installation procedure.
Installation steps can vary depending on the
type of installation.
1. Prepare the surface where the unit is to be mounted. Make sure that the surface is flat, vertical and that it supports
the weight of the unit. Perform the installation in accordance with local rules and regulations.
Total height of the unit with cooker hood connected by
minimum 100 mm flexible duct distance (D)
Distance to the mounting bracket from the underside
of the cooker hood or underside of the cupboard if it is
aligned with the cooker hood (mm)
Note:
This distance must be increased according to
the increased measurement D if flexible duct is
used.
850
815
212193 | v04