4. Configure room temperature sensor: Go to Input menu. Select ANALOG tab. Select the analog input to which the
sensor is connected. Example if it is connected to AI6 on the connection board, then select ANALOG INPUT 6. Select
input type as Room Air Temperature Sensor (RAT).

11.3 Temperature control

11.3.1

Internal electrical reheater

Warning
• The internal electrical reheater cannot be used if the unit is installed horizontally.
Electrical reheater is used for supply air heating during
cold outside temperatures. Electrical reheater should be
installed inside of the unit.
• ELH — Electrical heater
• OHT — overheat protection sensor
• 1 — Outdoor air
• 2 — Supply air
• 3 — Extract air
• 4 — Exhaust air
Component/product — Article number:
• Electrical Re-heater VTR 100/B 250W – 154100
1 Remove the cover of the unit.
Insert reheater (1).
212193 | v04
57
Accessories |