Parameterization and configuration
8.11.6 Scaling function
PNO CLASS 2 16 Bit
Defines whether the position is scaled according to the parameters
-
-
If Class 2 is switched off, the position value cannot be scaled or adjusted.
8.11.7 Scaling parameter PNO CLASS 2
Maximum steps per revolution: ≤ 8192
If higher resolutions are required, one of the TR-Modes must be used
If the scaling parameters are activated with the Scaling function, the physical
resolution of the measuring system can be changed. The position value output is
binary decoded and is calculated with a zero point correction and the count direction
set. The measuring system does not support decimal numbers in this configuration or
numbers of revolutions (gearbox function) deviating from exponents of 2.
8.11.7.1 Steps per revolution
Defines how many steps the measuring system outputs for one revolution of the
measuring system shaft.
Lower limit
Upper limit
Default
TR-Electronic GmbH 2004, All Rights Reserved
Page 96 of 115
Availability
"Measuring units per revolution"
"Total measuring range"
1 step / revolution
8192 steps per revolution (Max. value see nameplate)
4096
TR - ECE - BA - DGB - 00036 - 10
PNO CLASS 2 32 Bit
Printed in the Federal Republic of Germany
Page
85, 86
10/01/2014