8.11.9 Code PROFIBUS-Interface
Defines the output code for the PROFIBUS interface.
8.11.10 Limit switch lower and upper limit
TR-Mode High Resolution
Is the status switched on (see Teach-In function page 94 and Status-byte page 102)
the measuring system can inform the master via a bit whether the actual value is
within the limits.
Limit switch bit = 0
Process-actual value lower limit switch or
Process-actual value upper limit switch
Limit switch bit = 1
Process-actual value < lower limit switch or
Process-actual value > upper limit switch
The inputs depend on the total measuring length in increments.
Lower limit
Upper limit
Default Lower limit switch 0
Default Upper limit switch 4096
8.11.11 Velocity [1/x rpm]
With this parameter, the specified rotational speed can be scaled in arbitrary steps
between 1/1 and 1/100 rpm. The rotational speed is output as two's complement
value. CW = positive, CCW = negative, with view onto the flange connection.
Default = 1 rpm.
Printed in the Federal Republic of Germany
10/01/2014
TR-Mode Position
TR-Mode Position
TR-Mode Position+Velocity
TR-Mode High Resolution+Velocity
TR - ECE - BA - DGB - 00036 - 10
Availability
TR-Mode Position+Velocity
Availability
TR-Mode Position+Velocity
TR-Mode High Resolution+Velocity
0
programmed total measuring length in increments – 1
Availability
Page
87, 88
Page
87, 88
90, 91
Page
88
91