Cleaning the blower
The waste container must be raised.
Side cover
1
Blower chamber
2
1. Secure the waste container.
2. Pivot out the side cover.
3. Remove dirt from the fan grille and clean with a moist cloth.
Cleaning the vacuum system
Waste container emptied.
Motor running.
ATTENTION
Damage due to soiled vacuum system
A soiled vacuum system can lead to the blower fan running out-
of-round and to vehicle vibrations.
Check the vacuum system for soiling and clean if necessary.
1. Switch on the PTO.
2. Set the motor speed to approx. 2200 rpm
3. Switch on the blower fan.
4. Using a water hose, spray fresh water into the suction mouth
area.
The water is collected in the waste container. The cleaning
process is completed when clean water exits at the diffuser.
5. Empty waste container.
6. Keep running the blower to dry the waste container.
Contact Customer Service if, in spite of thorough cleaning, vi-
brations are still present (caused by the suction blower running
out-of-round).
Cleaning the water filter
1. Raise the waste container.
2. Open the left-hand advertising panel.
3. Unlock the water filter and remove it from the holder.
4. Unscrew the filter casing.
5. Clean the water filter.
6. Insert the filter.
7. Check for correct seating.
8. Screw the filter casing tight.
9. Place the water filter in the holder and lock it.
10.Close the left-hand advertising panel.
11.Lower the waste container.
Clean the spray nozzles
Note
The spray nozzles are located on the side brushes and suction
mouth.
1. Remove the spray nozzles.
2. Clean the spray nozzles with a brush/compressed air.
3. Install the spray nozzles.
106
Cleaning the recycling water valve
Bayonet connection
1
Recycling water valve
2
Waste container
3
1. Empty the waste container.
2. Raise the waste container.
3. Open the bayonet connection.
4. Remove the valve.
5. Clean the valve under running water.
6. Insert the valve.
7. Close the bayonet connection.
The fuses are located behind a cover behind the driver's seat.
Cover
1
Fuses
2
1. Open cover.
2. Replace defective fuses.
Note
Use only fuses with the same ampere rating.