Verfügbare Sprachen

Installation
9.5 Connecting the hob to the mains
• Make sure, that the data on the rating plate (V) matches your
supply voltage.
• The connection to the power supply must be carried out by a
qualified electrician in accordance with the relevant standard
or with a single-pole circuit breaker, as described below:
2 × 230V~, 2N~
16A
• The electrical connection must be made properly and
in accordance with the applicable safety regulations.
• To connect the hob to the mains power supply, do not use adapters,
reducers, or branching devices, as they can cause overheating and
fire.
• The cable must not be kinked or pinched.
• The power supply cable must not touch any hot parts and must be
positioned so that its temperature will not exceed 75˚C at any point.
• The cable must be checked regularly.
• If the cable is damaged or needs to be replaced, this must be done by
a qualified electrician with the correct tools .
• Use the supplied power cord for installation and replace it only with
one of the same type.
Note:
Hob blue and grey
connect in box on neutral / N .
Black on L1,
brown on L2.
blue and grey do not
disconnect!
1 × 220-240V ~
32A
Appliance is not suitable
for operation with an
EU plug!
77