Herunterladen Inhalt Inhalt Diese Seite drucken

Product Introduction; Applications; Pumped Liquids - Grundfos LSV Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für LSV:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 111
Check alignment, clamping coupling structure
Pos. Description
1
Leverage dial gauge
Recheck the coupling clearance and tighten the set
screws on the couplings.
Tightening torques
Description
Dimensions
M6
M8
M10
Hexagon
socket set
M12
screws
M16
M20
M24
WARNING
Crushing hazard
Death or serious personal injury
To protect persons from rotating
machine parts, always install coupling
guards after the installation is complete
and before starting the pump.
20
1
Tightening torque
[Nm]
10 ± 2
12 ± 2.4
23 ± 4.6
40 ± 8
80 ± 16
120 ± 24
120 ± 24

5. Product introduction

5.1 Applications

Grundfos LSV vertical split-case pumps are typically
used in these applications:
circulation in heating- and air-conditioning
systems, water condensing and boiler feed
systems
liquid transfer and pressure boosting in various
industrial systems
water distribution and water treatment in public
water systems.

5.2 Pumped liquids

Clean, thin, non-aggressive liquids, not containing
solid particles or fibres. Do not pump liquids that will
attack the pump materials chemically.
CAUTION
Hot Liquid
Minor or moderate personal injury
Do not exceed the maximum operating
temperature stated on the nameplate.
When pumping liquids with a density and/or viscosity
higher than that of water, the head and flow will be
reduced. Alternatively, use motors with
correspondingly higher outputs.
The stuffing box packing rings or mechanical shaft
seal O-rings chosen must be suitable for the liquid to
be pumped.
Special stuffing box packing rings or shaft seal O-
rings may be required if you use the pump for
pumping treated water:
at temperatures above 80 °C (176 °F).
containing additives to prevent system corrosion,
calcareous deposits, etc. (this may be the case in
heating and ventilating systems).
When pumping liquids other than water, select an
appropriate stuffing box or shaft seal. For further
information, contact Grundfos.