Technical Data

Input Data

Frequency
Nominal voltage
Max. input current

Interfaces

Modbus RTU
LAN
WLAN
Temperature sensor

Output Data

Analogue out 1-phase/3-phase
Analogue nominal voltage per phase
Analogue out short circuit current
Relay out max. current
Multifunctional relay out
Efficiency during rated operation
Consumption during standby

General Data

Dimensions (height x width x depth)
Weight
Degree of protection
Mounting
Ambient temperature range
Permitted humidity
Cooling
Storage temperature
EMC device class
Overvoltage category
Pollution level
RS 485, max. 1000 m, screened and twisted
Ethernet at least CAT5, screened
PT1000 (max. 30 m)
Continuously variable 0 - 3 / 0 - 9 kW
16 A (max. 5 seconds)
L2 / L3 16 A (max. 5 seconds)
min. 15 V / 2 mA; max. 16 A (max. 5 seconds)
340 mm x 270 mm x 123 mm
0%-99% (non-condensing)
50 Hz
230 V / 400 V
1 X 16 A / 3 x 16 A
IEEE 802.11 b/g/n
13 A
at least 98%
typically 1.8 W
3.9 kg
IP54
Wall
0 to 40 °C
Convection
-40 to 70 °C
B
3
3
95