In order to implement various settings, the WLAN connection must briefly be
opened as follows
1. Press the button on the Ohmpilot 2x. The blue LED flashes (twice) for as long as the
WLAN access point is active (30 minutes). Before the access point is opened, a search
for available WLAN networks is carried out.
2. Activate the "Ohmpilot" WLAN network on your smart device or PC.
3. Enter the website http://192.168.250.181 or http://ohmpilotW.local in the browser.
Alternatively, the Fronius Solar.web app can also be used to search for the Ohmpilot in
the network.
4. Implement the settings.
Establishing a
As standard, the Ohmpilot obtains its IP address automatically from the DHCP server,
Connection via
meaning that no settings are generally necessary.
LAN
The inverter automatically searches for the Ohmpilot, with the search process taking up
to 5 minutes. If the red LED is unlit and the green LED is flashing, the Ohmpilot is work-
ing correctly.
A static IP address can be assigned to the Ohmpilot via the web interface.
1. Open the website http://ohmpilotL.local. Alternatively, the IP address assigned by the
DHCP server can also be read off. Almost every router displays the devices connected to
it (its clients) on its web interface. Apps such as Fing can also help to find the IP address
that has been assigned automatically. Alternatively, the Fronius Solar.web app can also
be used to search for the Ohmpilot in the network.
In order to configure the IP address manually, the "static" option must be selected. Then
enter the IP address required.
The Ohmpilot can then be reached at http://ohmpilotL.local or at the fixed IP address
assigned.
NOTE! In networks with a DNS suffix, the Ohmpilot can be reached at http://
ohmpilotW.<DNS- Suffix>. E.g. http://ohmpilotW.fronius.com
NOTE! In networks with a DNS suffix, the Ohmpilot can be reached at http://
ohmpilotL.<DNS suffix>. E.g. http://ohmpilotL.fronius.com
87