Failure
Possible cause
Indicator lamp
Fuel tank empty.
flame monitoring,
The fuel filter is clogged
temperature limiter
Photocell flame monitoring is incorrectly
lights up
aligned or defective
Malfunction on the fuel pump or fuel sole-
noid valve
Indicator lamp
Temperature limiter has got triggered.
flame monitoring,
temperature limiter
is blinking
Display
Cause
E001
Set off the motor protection switch high
pressure pump
E002
Fuse - F1 has triggered, circulating
pump, heat fan
E003
Burner fault
E004
Tank permeate is empty (only with op-
tion Top-Care)
E005
Detergent, fuel empty (option)
E100
Interruption control circuit
Fault
Possible cause
Plant is not running
Mains fuse have got triggered
No pressure build-up in
Amount of water supply is too low.
the plant or pump is
Heating coil has heavy calcium depos-
knocking
its
Pipe is blocked
System is sucking air
Program 4 (optional, by
Wrong adjustment in the function men-
ABS half load program
ue
5) no function
No reduced pressure
when using program 2
(only with ABS half load)
Pump leaky (more than
Defective pump part
3 drops of water per min-
ute)
Detergent is not taken in Filter or hose is blocked
Magnet valve or check valve defect
Pump hose of the dosing pump dam-
aged.
high pressure pump
Detergent container is empty
does draw air
Burner does not ignite or
The hot water was not adjusted for this
the flame glows off dur-
washing program.
ing operation
No ignition
Too low water tempera-
Temperature has been set too low.
ture for hot water opera-
Heating coil has heavy calcium depos-
tions
its
Nozzle in spray pipe is rinsed out.
Heating coil sooted
Interruption with a display of the operating panel
Correction
Refill fuel tank.
Clean fuel filter.
Check the correct positioning of the photo-cell.
Check parts and replace defective parts.
Open the trigger gun until the system has cooled down.
Switch the system on and off at the operator panel in or-
der to unlock the temperature limiter. If the event re-
curs, call Customer Service.
Malfunctions with indication on the display
Correction
Reset the motor circuit breaker, in case of recurrence, call
Customer Service.
Switch off the system, wait briefly, switch on the system.
Refer to the operating instructions of the RO system (op-
tion).
Check the container, refill if necessary. Restart system.
Switch off the system, wait briefly, switch on the system.

Faults without display

Remedy
Check mains fuses and mains voltage
Check water supply level (refer to technical data).
base exchanger (optional) or water softener with RM
110 (optional) does not work. Rectify cause, decalcify
the plant.
Check all pipes to see that there are no blockages
Check system for leaks, the detergent suction hoses
must lie in the detergent, refill detergent container.
Check the pump hose for cracks and wear; replace if re-
quired.
Set the "Osmosis" function in the function menu to
"On".
Set the "Half-load" function in the function menu to
"On".
Replace defective part.
Clean the parts.
Replace valve.
Check the pump hose for cracks and wear; replace if re-
quired.
Refill detergent.
Check the adjusting the control circuit board
Check ignition.
Check ignition electrodes.
Set the thermostat to a higher level.
base exchanger (optional) or water softener with RM
110 (optional) does not work. Rectify cause, decalcify
the plant.
Define the quantity to be transported by the pump. Re-
place nozzle if the specifications given in the technical
data are exceeded with a large margin.
Remove the soot from the heating coil.
EN
13
-
By whom
Operator
Operator
Operator
Customer Ser-
vice
Operator
By whom
Operator
Operator
Operator
Operator
Operator
By whom
Operator
Operator
Operator, Cus-
tomer Service
Operator
Operator
Operator, Cus-
tomer Service
Operator, Cus-
tomer Service
Operator, Cus-
tomer Service
Customer Ser-
vice
Operator
Customer Ser-
vice
Operator, Cus-
tomer Service
Operator
Operator
Customer Ser-
vice
Customer Ser-
vice
Operator
Operator, Cus-
tomer Service
Operator
Customer Ser-
vice