FAULTS

Unit does not run
No mains voltage
– Check mains connection/power
cord
Unit does not build up pressure
Air in system
– Bleed pump:
* With handgun open, use selector
switch to switch unit on and off
several times.
* Check connections and lines
Strainer in water connection dirty
– Clean strainer
Insufficient water supply
– Check water supply volume (refer
to technical data)
The low pressure nozzle is mounted
or the multiple nozzle is set to
"CHEM"
– Install the high pressure nozzle or
set the multiple nozzle to "high
pressure"
Water drips out of the side of the
drain hose
Safety valve is open
– A quick opening of the safety
valve with each closing of the
handgun is normal and permitted
HDS 501 C / HDS 550 C
Unit leaking, water dripping out at
bottom
Pump leaking
– 3 droplets/min are permitted.
– In the event of a major leak, have
unit checked by After-Sales
Service.
Unit constantly switched on and
off with handgun closed
Leak in high-pressure system
– Check high-pressure system and
connections for leaks
Unit does not draw in cleaning
agent
Filter in cleaning-agent suction hose
dirty
– Clean filter
Non-return valve gummed up
– Pull the cleaning agent hose off
and detach the non-return valve
with a blunt object, see Figure 12
High-pressure nozzle is mounted
– Fit low pressure nozzle or switch
over multiple nozzle to "CHEM"
position.
Burner not ignited
Fuel tank empty
– Fill up
Lack of water
– Check water connection, check
supply lines, clean low water
protection.
Fuel filter dirty
– Replace fuel filter.
No ignition spark
– Have unit checked by After-Sales
Service if no ignition spark is
visible through inspection glass
during operation.
Set temperature not attained
when working with hot water
Soot deposits on heating coil
– Have After-Sales Service remove
soot deposits from unit
If the problem cannot be resolved
the unit must be checked by after
sales service.

WARRANTY

The warranty terms and conditions
issued by our responsible sales
company apply in every country.
Within the warranty period, any
faults in the unit will be rectified free
of charge provided that the problem
was caused by a material defect or
manufacturing error.
The warranty only applies if the
dealer fills in, stamps and signs the
enclosed reply card when the unit is
sold and the purchaser then returns
it to the appropriate local distributor.
In the event of a warranty claim,
please contact your dealer or the
nearest authorised After-Sales
Service office and produce both
accessories and proof of purchase.

GENERAL INSTRUCTIONS

Safety features
* Pressure switch
The pressure switch shuts off the
unit when the handgun is closed and
causes it to cut in again when the
handgun is opened.
* Safety valve
The safety valve opens quickly with
each closing of the handgun or
when the overflow valve or the
pressure switch is defective. Then
the out-flowing water escapes. The
safety valve is set at the factory and
sealed. Adjustment can only be
made by After-Sales Service.
* Low water protection
The low water protection stops the
burner being switched on in the
event of a lack of water. A strainer
stops the protection feature
becoming dirty and requires regular
cleaning.
* Motor thermal contact
The motor thermal contact interrupts
the electrical circuit when the motor
is overloaded.
15