– Power connection, refer to "technical
data".
– By customer, lockable, access for the
wash customer emergency - off- main
switch.
– Light at the washing area according to
the national requirements, in order to
assure safe working for the customer
when dark.
– Power and water supply according to
the measuring sheet.
– By operation in the winter, an isolated/
heated water supply sytem must be
guaranteed.
– Drain water shaft and required drain
water disposal.
– Drill fixing holes according to the meas-
ure sheet.
Unpack the equipment
Unpack the plant and sent the packaging
materials for recycling.
Aligning the unit and installing it
 Line up the equipment on the level area.
 Fix with the material included. Use the in-
closed spacer and set up the equipment
horizontal.
1 Dowel pin M10 (4x)
2 Unterlegplatte 5 mm (4x) Unterlegplatte
2 mm (4x)
3 Washer 10,5 (4x)
4 Hexagon screw M10 (4x)
Assemble the installation parts
Exhaust nozzle
 Place the exhaust nozzle from outside
on the roof and fasten it from inside us-
ing the enclosed screws.
Outside anti freeze thermostat
(optional)
 Install the outside thermostat, that it is
protected from direct sun light warm
walls and air flow.
 Connect the inclosed cable in the con-
trol circuit board ( refer to pwer flow
plan).
swinging spacer (optional)
 Install the swinging spacer according to
the enclosed installation instruction on
the left side of the equipment.
Cleaning tool
 Lead the high pressure hose through
the sidewall of the equipment and con-
nect with the high-pressure pump.
 Connect the high-pressure hose with
the blowing gun.
 Connect the steel pipe brush with the
blowing gun.
 Tighten all clamping nut.
Brief instruction
 remove the brief instructionfrom the in-
struction manual, and fix it inside the
door of the circuit control board.

Water connection

WARNING
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA.
Water flowing through a system separator
is considered non-drinkable.
CAUTION
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Note:
Impurities in the inlet water can damage the
system. Kärcher recommends the use of a
water filter (see "accessories").
ATTENTION
Risk of damage to the plant if water supply
is not of suitable quality. The system must
only be supplied with water in drinking wa-
ter quality.
Quality requirements for tap water:
Parameter
pH value
electrical conductivity
Hydrocarbons
Chloride
Calcium
Total hardness
Iron
Manganese
Copper
Sulphate
Active chloride
free of bad odours
For connection values refer to technical
specifications.
 Insert the inlet hose from the bottom
through the plant opening and connect
it.

Electrical connection

DANGER
Risk of electric shock!
The mains must be connected by an expe-
rienced electrician and the requirements of
the IEC 60664-1 must be fulfilled.
The plant must be secured through a wrong
current protection switch with a triggering
current lesser than or equal to 30 mA.
 Remove the 4 knurled scrwes from the
roof. The screws can be loosened fast-
er when you press the roof from the top.
 Push the chimney pipe upward until the
connection to the burner has been loos-
ened.
15
-
EN
 Push the roof towards the door until it
protrudes out of the casing on the oppo-
site side.
 Remove the roof upward. Caution! Do
not damage the chimney
 Connect the wire to the electrical switch
cabinet.
Note:
After completion, check the electrical con-
nection for right rotary field.
 Check the rotation direction of the high
pressure pump. With correct direction
of rotation a strong airflow can be felt
out of the exhaust opening of the burn-
er.
Adjusting the dosing of the softener
liquid (optional)
DANGER
Electrical hazard. Setting may only be done
by an electrician.
 Determining the hardness of tap water:
– through the public water supply works,
– Using hardness testing set, order no.
6.768-004.
 Open the switch box at the operator
panel.
Value
6,5...9,5
max. 2000
μS/cm
< 0.01 mg/l
< 250 mg/l
1 Speed potentiometer
< 200 mg/l
< 28 °dH
< 0.2 mg/l
< 0.05 mg/l
< 0.02 mg/l
< 240 mg/l
< 0.1 mg/l
 Locate the local water hardness in the
diagram.
 Extend the vertical line upward until the
curve for the corresponding point has
been reached.
 Draw a horizontal line from the intersec-
tion and read the setting value (A).
 Adjust the speed potentiometer to the
value that you have ascertained (A).
Example: For a water hardness of 15 °dH
on the scale for the SS wash 5/10, set the
speed potentiometer to position 7. This re-
sults in a pause of 40 seconds, i.e. the so-
lenoid valve will open briefly every 40 sec-
onds.
 Close the switch box at the operator
panel.
 Put the roof back on