Herunterladen Inhalt Inhalt Diese Seite drucken

Faults; Faults With Display - Kärcher B 40 W Bp Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
DANGER
Risk of injury! Before working on the appli-
ance, remove the Intelligent Key and the
mains plug of the charger.
 Drain and dispose of the dirt water and
the residual fresh water.
Display
ERR_I_BÜRSTE_049
ERR_I_TURB_050
ERR_U_BATT_001
If the display shows different error messag-
es or if the error cannot be remediated:
 Remove the Intelligent Key.
 Wait for 10 seconds.
 Plug in the Intelligent Key.
 If the fault recurs, call customer service.
Fault
Remedy
Appliance cannot be
Stand-by. Turn the appliance off and reinsert the Intelligent Key.
started
Turn the program selection switch to the desired programme.
Check battery; charge it if required.
Make sure that all battery terminals are connected.
Insufficient water quan-
Check fresh water level, refill tank if necessary.
tity
Increase the water volume on the regulating knob for water volume.
Unscrew the lock of the fresh water reservoir. Remove and clean the fresh water filter. Insert the filter and screw
in the lock.
Remove the water distribution strip from the cleaning head and clean water canal (only R cleaning head).
Check hoses for blockages; clean if required.
Do not add detergents Increase the water volume to activate the dosing pump.
Check the detergent level
Insufficient vacuum per-
Clean the seals between waste water tank and cover and check for tightness, replace if required.
formance
Wastewater reservoir is full; shut off the appliance and empty the wastewater reservoir
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Insufficient cleaning re-
Check the brushes for wear, replace if required.
sult
Brushes do not turn
Check if foreign matters block the brushes; remove foreign matter if required.
If over-current switch in the electronics system has been triggered, turn programme selection switch to "OFF".
Afterwards, set it back to the desired programme.
Vibrations during clean-
You might need to use softer brushes.
ing
In case of faults that cannot be remedied using the table below please contact the customer service.
22
Remedy
Check if foreign matters block the brushes; remove foreign matter if required.
Check suction turbine for contamination and clean it if necessary.
Check battery; charge it if required.
Faults without display on the console

Faults

Faults with display

9
-
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für: