Time
Activity
many times
check brush
daily
daily
Check interiors of the
plant
check brush shaft
check fuel tank
Cleaning the sieve
Clean the filter of the anti
freeze pump.
before the
Check frost protection de-
frosting period
vices
Clean the filter of the anti
freeze pump.
monthly or af-
check the anti freeze wa-
ter 160 oper-
ter amount at the anti
ating hours
freeze cycle
Shutdown
If the equipment is to be shut down, and
there is not danger of frost,
 disconnect the water input,
 disconnect the power supply.
Shutting down by danger of frost
 By the option of the base exchanger.
Disconnect the water input between the
base exchanger and the cooler.
 Rinse the equipment ( with base ex-
changer (optional)) with anti freeze
agent.
 Rinse the base exchanger with a con-
centrat salt agent.
 Empty all swimming cointainers, dis-
connect the pipes, and drain offf the wa-
ter.
 Empty the high pessure pump, discon-
nect the pipes from the high pressure
pump, and drain the water.
 Disconnect the high pressure pipe at
the head of the pump, and drain the wa-
ter.
 Store the cleaning agent container and
the fuel container at a non-freezen
place.
If not surtain when shutting down, please
call your local service.
Performance
check for dirt and ice, lock brush cleaning if necessary
Is the hot air blower working?
Is the drain to the swimming container free of ice?
Check filling level, refill if necessary
Open the screw (one top of the high-pressure pump), take out the strainer and
clean it, put the strainer back in, close the screws tight.
Clean the strainer and put it back in
Change the freezing thermostat in the direction of "check", until the anti freeze
equipment is turned on. Fan heater and freezing cycle must start. If the temper-
ature is above 5 °C in addition, turn the thermostat of the fan heater up. Then
turn the frost protection thermostat in an anti-clockwise direction until the stop.
Reset the thermostat of the hot air blower.
Note:
The openings in the device socket must not be closed, otherwise the function of
the frost protection thermostat is disturbed.
Clean the filter and replace
Target value: approx. 0.5 l/min per washing tool
Water quantity is higher: Change the node piece in the hand-spray gun.
WARNING
Risk of injury and damage. If the frost protection water volume is bigger than the
admissible value, the cleaning tool may move uncontrollably due to the exiting
water stream. If the frost protection water volume is too big, replace the union
piece in the trigger gun by all means.
Water quantity is lesser Clean filter for frost protection pump; clean sieve in throt-
tle, clean pipes, check the rotation direction of the pump.
EN
7
-
By whom
Operator
Operator
Operator
Operator
Operator
Operator
31