Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Display
ERR B
ERR T
LOW BAT
ERR TEMP
HandsOff
ERR REL
Fault
Appliance cannot be started
Insufficient water quantity
Insufficient vacuum perform-
ance
Insufficient cleaning result
Brushes do not turn
30

Faults with display

Remedy
Check if foreign matters block the brushes; remove foreign mat-
ter if required.
Call customer service.
Charging battery
Allow device to cool down.
Reduce brush contact pressure, if necessary.
Release the control handle and wait until the operating hours or
the battery status is shown in the display. After that, activate the
control handle again.
Turn off the switch for brush operation, turn off the switch for the
vacuum turbine, release the control handle, wait 3 seconds and
turn back on.
If the event recurs, call Customer Service.
Faults without display on the console
Remedy
Press control switch.
Check battery; replace, if needed.
Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.
Clean the seals between dirt water reservoir and cover
and check for tightness, replace if required.
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, turn or replace
if required
Check if the suction hose and vacuum bar are chocked,
clean if required
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is
closed
Check the setting of the vacuum bar.
Check the brushes for wear, replace if required.
Press control switch.
Check if foreign matters block the brushes; remove for-
eign matter if required.
– 12
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis