7.3.3

Mounting with threaded bushing

The sensor can be used for quasi-static measurements with this type of
mounting. Dynamic loads are acquired correctly. The sensor must not be ex­
posed to any tensile forces with this type of mounting.
This type of mounting offers a way to use the force transducer when it is not
possible to insert screw in the four threaded connectors on the force applica­
tion part.
The threaded bushings are included in the scope of supply.
Screw the threaded bushings into the fine threading of the sensor. Use a screw
of property class 12.9 to fasten the sensor onto your structural element (see
Fig. 7.3). Make certain that at least six threads are used and observe the
torques as specified in the table below.
Sensor
CFT+/25kN
CFT+/50kN
CFT+/70kN
CFT+/120kN
CFT+
DIN 912 bolt
M2
M4
M6
M10
A05101_01_YCI_02 HBM: public
Mechanical installation
M
[Nm]
0.25
1
3.5
15
19