Interval
Where?
every month
as required
as required
GB
B50 GSM
102
What?
How?
Oil the drilling column in regular intervals using standard oil.
Lubricate the toothed rack in regular intervals using standard
grease.

original parts or series components expressly authorized by Opti-
mum Maschinen Germany GmbH. on page 103
Oil the toothed rack (toothing) and the drill sleeve in regular inter-
vals using standard oil.
The coolant pump is maintenance-free.
Replace the cooling agent regularly, depending on usage.
Rinse the coolant pump if you use coolants that leave residues.
If the light bulb is defective:
Unscrew the glass cover of the machine illumination.
Unscrew the light bulb by turning it to the left and by slightly
pressing the bulb into the socket (bayonet).
Replace the light bulb.
Screw the glass cover onto the machine illumination.
Img.7-8:
Machine illumination


Inspection plan for water-mixed cooling lubricants on page 105
Originalbetriebsanleitung
Cooling lubricants and tanks on page 104
Machine illumination