Interval
Where?
at the begin-
ning of the
shift
after every
maintenance
or repair work
GB
B50 GSM
100
What?
How?
Check the oil level in the inspection glass The glass oil level (
deposed ) should be half-covered.
Img.7-5:
Functional diagram of the lubrication system
ATTENTION!
The geared drill is delivered without operating material
(oil, coolant). Fill in first oil and coolant before
commissioning.
Fill the gearbox with gear oil.
Originalbetriebsanleitung
Filler hole
Oil flow during opera-
tion
Oil drain plug
Oil sight glass
Img.7-4: Oil level of the gear of the drilling spindle
sleeve
Version 1.1.4 - 2021-01-04