The units are provided with load and speed-sensitive overload protection and thermal
memory retention upon shutdown or power loss.
The trip current is adjusted to 150 % of the rated motor current.
The units are suitable for a maximum surrounding air temperature of 40  °C, max.
60 °C with derated output current.
To determine output current rating at higher than 40 °C, the output current should be
derated 3.0 % per °C between 40 °C and 60 °C.
The units are for use in pollution degree 2 environments.
®