10.
Technical Data
10.1
Lub-O-Dry-Exx
Pump
Performance
Applicator back pressure
Air pressure control
Air use
Compressed air connection
Conveyor belt lubricant connection:
Number of lubrication circuits:
Dimensions (H x W x D)
Weight
Material:
10.2
Lub-O-Dry-Exx
Power supply
Control voltage
Received power
Back-up fuse
Control module
Display/operation
No. of lubricating circuits
No. of systems
Weight
Dimensions
Case material
Protection class
Fixation method
Please change the battery of the steering unit after 5 years, if not you can loose data of
system and variable data.
IMPORTANT
Please change the battery only with power on the steering unit.
Type of batterie: 3 Volt, lithium, CR2450 (5mm)
417101633_DryExx_Basic
- Hardware
Diaphragm compressed air pump
0 - 25 l/min
max. 0.7 MPa (7 bar)
max. 0,7 MPa (7 bar)
approx. 0.2 Nm³/h
8/6 / 10/8 mm
suction side
12/21 x 4.5 PVC fabric hose
pressure side
R ¾"
dependent on control unit
550 x 410 x 220 mm
approx. 10 kg
Console / Cover
Stainless steel
- Control System
DryExx
120-500 V, 50/60 Hz
max.24 V/DC
max.250 W
max.10 A
Unitronics „Vision 130" with integrated display
Integrated display panel
max. 8
max. 1
approx. 20 kg
500 x 500 x 210 mm (W x H x D)
Stainless steel
IP 65
Fixation to wall
®
- Basic
- 39 -