Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; General Data; Specific Data - ECOLAB Lub-O-Mat 2,5 Betriebsanleitung

Dosierstation für die bandschmierung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10.

Technical Data

10.1

General Data

Pulse distance water counter
Fresh water supply line
Consumer connection
Water pressure
Power supply
Electrically connected load
Pre-fuse
Input water temperature
Ambient temperature
Emission sound pressure level
Protection level
Dimensions
Weight
Housing
10.2

Specific data

Metering pump capacity
Metering rate per stroke
IMPULS
Division
Multiplikation
417101637_Lub-O-Mat
150 ml/Imp.
G ¾" a
G ¾" a
5 – 8 bar
5 – 6 bar
2,5 l/h
230 V, 50
4,3 l/h
230 V, 60 Hz
7,2 l/h / 11,2 l/h
95-265 V, 50 / 60 Hz
100 VA
10 A
40°C
5 - 40°C
< 70 dB (A)
IP65
550 x 410 x 220 mm (w x h x d)
12,5 kg
Stainless steel
Lub-O-Mat
Pulsefactor
Flow capacity
2
2200 l/h
1
1100 l/h
2
550 l/h
(Lub-O-Mat
2.5/4.3/7.2)
(Lub-O-Mat
11.2)
(spezial version)
2.5
Lub-O-Mat
max. 2.5 l/h
max. 4.3 l/h
max. 0.34 ml
max. 0.57 ml
0.035-0.11 %
0.07-0.22 %
0.14-0.45 %
- 46 -
4.3
Lub-O-Mat
7.2
Lub-O-Mat
max. 7.2 l/h
max. 0.98 ml
Concentration
0.06-0.2 %
0.1-0,33 %
0.12-0.38 %
0.2-0,65 %
0.24-0.77 %
0.4-1,3 %
11.2
max. 11.2 l/h
max. 1.5 ml
0.15-0.5 %
0.3-1.0 %
0.6-2.0 %
Rev. 03-07.12