Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of The Unit; Flow Chart - Kärcher SB OB Originalbetriebsanleitung

Sb-waschanlage
Vorschau ausblenden Andere Handbücher für SB OB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Fresh water fine filter, on site
1
1
Salt tank
2
Hardness sensor 1
3
Base exchanger control head 1
4
Base exchanger bottle 1
5
2
RO membranes
6
2
Pressure gauge
7
2
Distribution block
8
2
Pressure sensor
9
2
Throttle
10
2
Soft water solenoid valve
11
2
Permeate buffer tank
12
BUFFER TANK FULL level switch
13
BUFFER TANK EMPTY level switch
14
2
Permeate solenoid valve
15
Detergent check valve
16
Half load bypass valve with throttle
17
High-pressure pump
18
Pressure relief valve
19
Check valve and frost protection throttle
20
Trigger gun with washing brush (1-tool version)
21
Dosing pump
22
Detergent suction hose
23
Detergent suction filter with foot valve
24
Power foam lance (3-tool version)
25
High-pressure gun with spray lance
26
5
Foam lance
27
5
Foam solenoid valve
28
24

Description of the unit

High pressure solenoid valve (option)
29
Power foam lance solenoid valve
30
Warm water solenoid valve
31
Cold water solenoid valve
32
Hot water temperature sensor
33
Electrical heating element
34
Temperature limiter
35
Dry running sensor
36
Hot water float tank
37
Cold water float tank
38
7
Sieve
39
Frost protection ball tap
40
2
Frost protection pump
41
2
Frost protection pump filter
42
7
Throttle
43
Frost protection float tank
44
3
Frost protection solenoid valve
45
Ultra-fine filter
46
1
only for water softening option
2
only for reverse osmosis option
4
3
only for high-pressure pump type 908
4
only for frost protection option (all variants)
5
only for 2- and 3-tool version
6
only for 3-tool version
7
only for antifreezing circulation
8
only for frost protection with lost water
5

Flow chart

5
6
7
7
7
7
8
2
English
System disconnection attachment kit
(optional)
For the system
1
Pump attachment kit disconnection from mains (op-
2
tional)
Float container
3
Water supply from the water pipe network
4
Monitoring and safety devices
Pressure relief valve
If the lever of the high-pressure gun is released, the cir-
culation valve opens but the high-pressure pump re-
mains in operation. The high-pressure jet is immediately
available when the trigger gun is opened again.
Motor circuit breaker
The motor circuit breaker shuts off the device if power
consumption is too high.
Winding protection contact
A winding protection contact is only installed in models
with 900 l/h.
The winding protection contact in the motor winding of
the pump drive sends a signal to the controller in the
case of thermal overload. This switches the motor off.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis