Description and function

6.1

Description of the product

Installation and operating instructions Wilo-CronoLine-IL-E, CronoTwin-DL-E, CronoBloc-BL-E
• IF-Module LON for connection to the LONWORKS network
• IF-Module BACnet
• IF-Module Modbus
• CAN IF-Module
• Smart IF module
For a detailed list, consult the catalogue and spare parts documentation.
NOTICE:
IF-Module may only be plugged in when the pump is de-energised
(voltage-free).
The pumps described here are single-stage low-pressure centrifugal
pumps with a compact construction and a coupled drive. The pumps
can be installed both directly as a pipe installation pump in a suffi-
ciently anchored pipe or placed on a foundation base.
The pump housing of the IL-E and the DL-E is configured in an in-line
design, i.e. the flanges on the suction and pressure sides are located
in the same axis. All pump housings are provided with pump support
feet. Installation on a foundation base is recommended.
NOTICE:
Blind flanges, which allow the motor impeller unit to be replaced even
in double pump housing, are available for all pump types/frame sizes
in the DL-E series (see chapter 5.4 "Accessories" on page 70). A drive
can therefore remain in operation while replacing the motor impeller
unit.
The pump housing in the BL-E series is a spiral pump housing with
flange dimensions in accordance with DIN EN 733. A pedestal screwed
onto the pump is available for motor powers up to 4 kW. From a motor
power of 5.5 kW or greater, cast or screwed-on feet are attached to
pump type BL-E.