Technical data

Charging output house battery
Charge/buffer/load current, regulated
Reduced charge/buffer/load current, DIP switch
position "OUT LIMIT
Input starting battery
Nominal battery voltage
Recommended battery capacity
Input voltage range (EURO 6 +), D+ controlled
Input over-voltage cutoff (EURO 6 +)
Max. power consumption
Max. current consumption
• Current consumption active, DIP switch position
"IN LIMIT"
• Current consumption limited, 3 positions of the
DIP switch "IN LIMIT"
Activation-control "D+" input, for D+/ terminal 15
TR terminal, load relay/max.
Lead batteries
• Nominal battery voltage
• Recommended battery capacity
• Maximum pre-charge current of a deeply dis-
charged battery (<8 V)
• Minimum battery voltage for start of charging
• Protection charge voltage at battery over-tem-
perature
LiFePO4 batteries
• Nominal battery voltage
• Recommended battery capacity
• Protection charge voltage at battery under-/over-
temperature
Under-voltage cutoff
32
MT LB 50
0 A – 50 A
0 A – 45 A
12 Vg
60 Ah
10.5 – 16.5 V
> 16.5 V
700 W
0.1 – 68 A
49 A, 42 A, 33 A
8 – 16 V
12 V/1 A
12 Vg
75 – 300/ 400 Ah 100 – 400 / 520 Ah 150 – 600/ 800 Ah
25 A
0 V
12.8 V
12 – 13.3 Vg
90 – 300/ 400 Ah 100 – 400/ 520 Ah 150 – 600/ 800 Ah
12.8 V
< 12 V
4445103618
MT LB 60
0 A – 60 A
0 A – 50 A
12 Vg
60 Ah
10.5 – 16.5 V
> 16.5 V
905 W
0.1 – 82 A
67 A, 55 A, 43 A
100 A, 82 A, 64 A
8 – 16 V
12 V/1 A
12 Vg
30 A
0 V
12.8 V
12 – 13.3 Vg
12.8 V
< 12 V
MT LB 90
0 A – 90 A
0 A – 75 A
12 Vg
100 Ah
10.5 – 16.5 V
> 16.5 V
1350 W
0.1 – 125 A
8 – 16 V
12 V/1 A
12 Vg
45 A
0 V
12.8 V
12 – 13.3 Vg
12.8 V
< 12 V