6.4

Electrical Installation

Block Diagram

6.4.1
The analog output is an active source of 4–20 mA.
The switch out is a passive n-switching Power MOSFET. The switch is normally open.
There is contact between the plug housing and the CS housing.
Connection Cable (option see section 16)
6.4.2
Our accessories list includes cables, one connector (M12x1, 8-pole female, specified in DIN
VDE 0627). The associated color code is shown in the table below.
HYDAC Filtertechnik GmbH
BeWa CS1000 3247149-02j en.doc
All manuals and user guides at all-guides.com
Pin
Color
1
White
2
Brown
3
Green
4
Yellow
5
Grey
6
Pink
7
Blue
8
Red
case
en
Installation and Operation
Supply voltage 9 – 36V DC
GND for supply voltage
RS485 +
RS485 -
Not to be connected
Analog out +
GND
for Analog out and Switch out
Switch out (normally open)
Connection to
Supply voltage 9–36 VDC
Analog out + (active)
GND supply voltage
GND Analog out / Switch out
Not to be connected
RS485 +
RS485 -
Switch out (passive, n.o.)
-
Shield