Herunterladen Inhalt Inhalt Diese Seite drucken

Sae As 4059; Sae As 4059 Table - HYDAC International ContaminationSensor CS 1000 Serie Betriebs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für ContaminationSensor CS 1000 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14.2

SAE AS 4059

The analysis Methods can be applied in the same manner as ISO 4406:1999.
The SAE cleanliness classes are based on particle size, number and distribution. The
particle size determined depends on the measurement process and calibration; consequently
the particle size are labeled with letters (A-F).
The following table shows the cleanliness in relation to the particle concentration determined.

SAE AS 4059 table:

14.2.1
Size ISO
> 4 µm
(c)
11171
Size Code
A
000
195
00
390
0
780
1
1,560
2
3,120
C
3
6,250
L
4
12,500
A
S
5
25,000
S
6
50,000
E
S
7
100,000
8
200,000
9
400,000
10
800,000
11
1,600,000
12
3,200,000
HYDAC Filtertechnik GmbH
BeWa CS1000 3247149-02j en.doc
All manuals and user guides at all-guides.com
Maximum Particle count / 100 ml
> 6 µm
> 14 µm
(c)
(c)
B
C
76
14
152
27
304
54
609
109
1,220
217
2,430
432
4,860
864
9,730
1,730
19,500
3,460
38,900
6,920
77,900
13,900
156,000
27,700
311,000
55,400
623,000
111,000
1,250,000
222,000
en
Tables - ISO 4406 / SAE AS 4059
> 21 µm
> 38 µm
> 70 µm
(c)
(c)
D
E
3
1
5
1
10
2
20
4
39
7
76
13
152
26
306
53
612
106
1,220
212
2,450
424
4,900
848
9,800
1,700
19,600
3,390
39,200
6,780
(c)
F
0
0
0
1
1
2
4
8
16
32
64
128
256
512
1,020
Page 128
2005-10-12

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cocos 1000

Inhaltsverzeichnis