Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of The Switching Output In The Measuring Modes; Mode M1: Measure Continuously; Mode M2: Measure Continuously And Switch; Mode M3: Filter Down To Contamination Level And Stop - HYDAC International ContaminationSensor CS 1000 Serie Betriebs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für ContaminationSensor CS 1000 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ContaminationSensor CS
8.3

Description of the Switching Output in the Measuring Modes

Mode M1: Measure continuously

8.3.1
Function:
8.4

Mode M2: Measure continuously and switch

Function:
8.5

Mode M3: Filter down to contamination level and stop

Function:
8.6

Mode M4: Filter to establish contamination levels continuously

Function:
8.7

Mode M5: Single measurement

Function:
HYDAC Filtertechnik GmbH
BeWa CS1000 3247149-02j en.doc
All manuals and user guides at all-guides.com
Continuous measurement of solid contamination,
without any switching functions
Continuous measurement of solid contamination,
continuous surveillance of programmable threshold,
if threshold is exceeded, the switching output is activated
to monitor an alert on site
Control of the filter units pump,continuous measurement of
solid contamination with some switching functions,
if pre-programmed cleanliness level is reached 5 times in
sequence, the pump is stopped
Control of the filter units pump,
continuous measurement of solid contamination with some
switching functions, if pre-programmed min/max levels are
exceeded, the pump is switched on/off to keep cleanliness
within range
Single measurement of solid contamination,
without any switching functions