ContaminationSensor CS
8.3
Description of the Switching Output in the Measuring Modes
Mode M1: Measure continuously
8.3.1
Function:
8.4
Mode M2: Measure continuously and switch
Function:
8.5
Mode M3: Filter down to contamination level and stop
Function:
8.6
Mode M4: Filter to establish contamination levels continuously
Function:
8.7
Mode M5: Single measurement
Function:
HYDAC Filtertechnik GmbH
BeWa CS1000 3247149-02j en.doc
All manuals and user guides at all-guides.com
Continuous measurement of solid contamination,
without any switching functions
Continuous measurement of solid contamination,
continuous surveillance of programmable threshold,
if threshold is exceeded, the switching output is activated
to monitor an alert on site
Control of the filter units pump,continuous measurement of
solid contamination with some switching functions,
if pre-programmed cleanliness level is reached 5 times in
sequence, the pump is stopped
Control of the filter units pump,
continuous measurement of solid contamination with some
switching functions, if pre-programmed min/max levels are
exceeded, the pump is switched on/off to keep cleanliness
within range
Single measurement of solid contamination,
without any switching functions
en
Installation and Operation
Page 102
2006-01-04