ContaminationSensor CS
15
Removing the CS from the Hydraulic System
1.
Remove electric plug from CS.
2.
Remove the hydraulic measurement line from the hydraulic system first, then
from the INLET port of the CS.
3.
Remove the hydraulic return-flow line from the OUTLET port of the CS.
4.
The CS can now be removed.
15.1
Disposal / Recycling and Decommissioning
The packing material is to be disposed of as specified by law or national regulations.
It can be reused.
When decommissioning and/or disposing of the CS, adherence is to be maintained to local
guidelines and regulations pertaining to occupational safety and environmental protection.
This applies in particular to the oil in the unit, components covered with oil and electronic
components.
After disassembling the unit and separating the various materials, they can be reused or
disposed of properly in accordance with local regulations.
16
Spare parts and Accessories
Description
Connection cable
(Socket M12x1, 8-pol. <-> open-end), Length = 2 m
Connection cable
(Socket M12x1, 8-pol. <-> open-end), Length = 5 m
Connection cable
(Socket M12x1, 8-pol. <-> Plug M12x1, 8-pol.), Length = 5 m
Socket (M12x1, 8-pol. angled, with soldering tag)
CD with - PC-Software package CoCoS 1000 and
- Operation and Maintenance Instruction
Contamination Sensor Interface CSI-D-5
O-ring for flange connection model (Material = FPM)
HYDAC Filtertechnik GmbH
BeWa CS1000 3247149-02j en.doc
All manuals and user guides at all-guides.com
en
Removing, Disposal
Qty. Part no.
1
6043041
1
6043044
1
6043689
1
6xxxxxx
1
3251484
1
3249563
1
6003048
Page 129