ContaminationSensor CS
The current (4-20 mA) corresponds to an SAE class or an error (described in the following
table and diagram):
9.1.1.1

I/SAE analog output characteristic

Current I
I < 4.0mA
4.0mA < I < 4.1mA
4.1mA < I < 4.3mA
4.3mA < I < 4.5mA
4.5mA < I < 4.8mA
I = 4.80mA
I = 4.90mA
I = 5.01mA
...
I = 5.83mA
I = 6.86mA
I = 7.89mA
I = 8.91mA
I = 9.94mA
I = 10.97mA
I = 12.00mA
I = 13.03mA
I = 14.06mA
I = 15.09mA
I = 16.11mA
I = 17.14mA
I = 18.17mA
...
I = 18.99mA
I = 19.10mA
I = 19.20mA
19.2mA < I < 19.5mA
19.5mA < I < 19.7mA
19.7mA < I < 19.8mA
19.8mA < I < 20mA
Range 4.8 to 19.2 mA corresponds to SAE class 0.0 to 14.0 (resolution 0.1 class)
• The current can be calculated for a given SAE class as follows:
I = 4.8 mA + SAE class * (19.2 mA - 4.8 mA) / 14
• The SAE class can be calculated for a given current as follows:
SAE class = (I-4.8 mA)*(14/14.4 mA)
HYDAC Filtertechnik GmbH
BeWa CS1000 3247149-02j en.doc
All manuals and user guides at all-guides.com
Description
Cable break
Device error, device not ready
Not defined
Flow error (flow too low)
Not defined
SAE 0
SAE 0.1
SAE 0.2
...
SAE 1
SAE 2
SAE 3
SAE 4
SAE 5
SAE 6
SAE 7
SAE 8
SAE 9
SAE 10
SAE 11
SAE 12
SAE 13
...
SAE 13.8
SAE 13.9
SAE 14.0
Not defined
Flow error (flow to high)
Not defined
no measured value
en
Installation and Operation
Page 105
2006-01-04

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cocos 1000

Inhaltsverzeichnis