SAE Class A/B/C/D (
9.1.2
The SAE class A/B/C/D measured value consists of 4 measured values coded with the
following time slices (also shown in the following diagram):
Identifier size code A: 19.2 mA for 300 ms + 4.8 mA for 300 ms
Measured value size code A: measured value for 3000 ms
Identifier size code B: 19.2 mA for 300 ms + 4.8 mA for 300 ms + 19.2 mA for 300 ms +
4.8 mA for 300 ms
Measured value size code B: measured value for 3000 ms
Identifier size code C: 19.2 mA for 300 ms + 4.8 mA for 300 ms + 19.2 mA for 300 ms +
4.8 mA for 300 ms + 19.2 mA for 300 ms + 4.8 mA for 300 ms
Measured value size code C: measured value for 3000 ms
Identifier size code D: 19.2 mA for 300 ms + 4.8 mA for 300 ms + 19.2 mA for 300 ms +
4.8 mA for 300 ms + 19.2 mA for 300 ms + 4.8 mA for 300 ms + 19.2 mA for 300 ms +
4.8 mA for 300 ms
Measured value size code D: measured value for 3000 ms
For the individual I/SAE analog output characteristics, see table 9.1.1.1.
9.1.2.1
Time-coded signal I/SAE — diagram